The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee, Knee Surgery, Sports Traumatology, Arthroscopy, vol.248, issue.3, pp.629-664, 2013. ,
DOI : 10.1007/s00167-012-1994-6
Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty, Knee Surgery, Sports Traumatology, Arthroscopy, vol.262, issue.1, pp.2296-300, 2013. ,
DOI : 10.1007/s00167-012-2005-7
Pr??cision des coupes osseuses dans l???arthroplastie totale du genou ?? l???aide d???un ancillaire conventionnel, Revue de Chirurgie Orthop??dique et R??paratrice de l'Appareil Moteur, vol.92, issue.3, pp.248-56, 2006. ,
DOI : 10.1016/S0035-1040(06)75732-4
The accuracy of femoral intramedullary guides in total knee arthroplasty, The Journal of Arthroplasty, vol.12, issue.6, pp.677-82, 1997. ,
DOI : 10.1016/S0883-5403(97)90141-8
Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty, The Journal of Arthroplasty, vol.28, issue.3, pp.469-73, 2013. ,
DOI : 10.1016/j.arth.2012.07.012
Patient specific cutting blocks are currently of no proven value, Journal of Bone and Joint Surgery - British Volume, vol.94, issue.11_Supple_A, pp.95-104, 2012. ,
DOI : 10.1302/0301-620X.94B11.30834
URL : http://doi.org/10.1302/0301-620x.94b11.30834
Evaluation of the accuracy of a patient-specific instrumentation by navigation, Knee Surgery, Sports Traumatology, Arthroscopy, vol.21, issue.1, pp.2194-2203, 2013. ,
DOI : 10.1007/s00167-012-2098-z
Do Patient-specific Guides Improve Coronal Alignment in Total Knee Arthroplasty?, Clinical Orthopaedics and Related Research??, vol.24, issue.suppl 2, pp.895-902, 2012. ,
DOI : 10.1007/s11999-011-2222-2
URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3270188
Patient-specific Total Knee Arthroplasty Required Frequent Surgeon-directed Changes, Clinical Orthopaedics and Related Research??, vol.20, issue.1, pp.1-6 ,
DOI : 10.1007/s11999-012-2573-3
URL : http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3528928
Alignment in total knee arthroplasty, The Journal of Bone and Joint Surgery, vol.86, issue.5, pp.682-689, 2004. ,
DOI : 10.1302/0301-620X.86B5.14927
Navigated total knee replacement. A meta-analysis, J Bone Joint Surg Am, vol.89, pp.261-270, 2007. ,
DOI : 10.2106/00004623-200702000-00005
Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies, International Orthopaedics, vol.440, issue.Suppl 2, pp.331-340, 2011. ,
DOI : 10.1007/s00264-010-1008-6
Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?, Knee Surgery, Sports Traumatology, Arthroscopy, vol.451, issue.Suppl 10, pp.1307-1329, 2012. ,
DOI : 10.1007/s00167-011-1588-8
Alignment outcomes in navigated total knee arthroplasty: a meta-analysis, Knee Surgery, Sports Traumatology, Arthroscopy, vol.299, issue.6, pp.1075-82, 2012. ,
DOI : 10.1007/s00167-011-1695-6
Meta-Analysis of Navigation vs Conventional Total Knee Arthroplasty, The Journal of Arthroplasty, vol.27, issue.6, pp.1177-82, 2012. ,
DOI : 10.1016/j.arth.2011.12.028
Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery, The Journal of Arthroplasty, vol.22, issue.8, pp.1097-106, 2007. ,
DOI : 10.1016/j.arth.2007.08.001
Accuracy of navigation: a comparative study of infrared optical and electromagnetic navigation, Orthopedics, vol.31, 2008. ,
Precise landmarking in computer assisted total knee arthroplasty is critical to final alignment, Journal of Orthopaedic Research, vol.88, issue.5, pp.1355-1364, 2010. ,
DOI : 10.1002/jor.21139
Osteoporosis affects component positioning in computer navigation-assisted total knee arthroplasty, The Knee, vol.19, issue.3, pp.203-210, 2012. ,
DOI : 10.1016/j.knee.2011.02.010
Bone cutting errors in total knee arthroplasty, The Journal of Arthroplasty, vol.17, issue.6, pp.698-705, 2002. ,
DOI : 10.1054/arth.2002.33564
How Does Electromagnetic Navigation Stack Up Against Infrared Navigation in Minimally Invasive Total Knee Arthroplasties?, The Journal of Arthroplasty, vol.23, issue.4, pp.573-80, 2008. ,
DOI : 10.1016/j.arth.2007.07.005
Interobserver and Intra-observer Errors in Obtaining Visually Selected Anatomical Landmarks During Registration Process in Non???Image-Based Navigation-Assisted Total Knee Arthroplasty, The Journal of Arthroplasty, vol.22, issue.8, pp.1150-61, 2007. ,
DOI : 10.1016/j.arth.2006.10.010
Torsion distale f??morale du genou??: comparaison de la mesure par tomodensitom??trie et par navigation perop??ratoire au cours des arthroplasties totales de genou, Revue de Chirurgie Orthop??dique et R??paratrice de l'Appareil Moteur, vol.94, issue.6, pp.573-582, 2008. ,
DOI : 10.1016/j.rco.2008.03.039
BoneMorphing versus freehand localization of anatomical landmarks: Consequences for the reproducibility of implant positioning in total knee arthroplasty, Computer Aided Surgery, vol.10, issue.5-6, pp.301-310, 2005. ,
DOI : 10.1097/00003086-200011000-00007
Intraobserver Errors in Obtaining Visually Selected Anatomic Landmarks During Registration Process in Nonimage-based Navigation-assisted Total Knee Arthroplasty, The Journal of Arthroplasty, vol.20, issue.5, pp.591-601, 2005. ,
DOI : 10.1016/j.arth.2005.02.011
Les coupes osseuses : tibiale, fémorale, rotulienne . 9 èmes Journées lyonnaises de chirurgie du genou et de l'épaule, pp.9-20, 1999. ,
Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?, Knee Surgery, Sports Traumatology, Arthroscopy, vol.35, issue.10, pp.44-50, 2008. ,
DOI : 10.1007/s00167-007-0399-4