,
, A Novel Method for Estimating Myocardial Strain: Assessment of Deformation Tracking Against Reference Magnetic Resonance Methods in Healthy Volunteers, Sci. Rep, vol.6, p.38774, 2016.
,
Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction, J. Cardiovasc. Magn. Reson, vol.19, p.12, 2017. ,
Simultaneous multislice (SMS) imaging techniques, Magn. Reson. Med, vol.75, pp.63-81, 2016. ,
Use of multicoil arrays for separation of signal from multiple slices simultaneously excited, J. Magn. Reson. Imaging JMRI, vol.13, pp.313-317, 2001. ,
,
, Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA), Magn. Reson. Med, vol.55, pp.549-556, 2006.
,
, Simultaneous multislice imaging in dynamic cardiac MRI at 7T using parallel transmission
, Magn. Reson. Med, vol.77, 2017.
CAIPIRINHA accelerated SSFP imaging, Magn. Reson. Med, vol.65, pp.157-164, 2011. ,
FLASH imaging: rapid NMR imaging using low flip-angle pulses, J. Magn. Reson. San Diego Calif, vol.213, pp.533-541, 1986. ,
Cardiac cine MR-imaging at 3T: FLASH vs SSFP, J. Cardiovasc. Magn. Reson. Off. J. Soc ,
, Cardiovasc. Magn. Reson, vol.8, pp.709-715, 2006.
Simultaneous multislice imaging (SIMUSIM) for improved cardiac imaging, Magn. Reson. Med, vol.10, pp.145-155, 1989. ,
SIMA: simultaneous multislice acquisition of MR images by Hadamard-encoded excitation, J. Comput. Assist. Tomogr, vol.12, pp.1026-1030, 1988. ,
Autocalibrating CAIPIRINHA: Reformulating CAIPIRINHA as a 3D Problem, Proceedings of the 20th Annual Meeting of ISMRM ,
Three-dimensional Fourier Encoding of Simultaneously Excited Slices: Generalized Acquisition and Reconstruction Framework ,
, Med. Off. J. Soc. Magn. Reson. Med. Soc. Magn. Reson. Med, vol.71, pp.2071-2081, 2014.
Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging ,
, Magn. Reson. Med, vol.53, pp.684-691, 2005.
Interslice leakage artifact reduction technique for simultaneous multislice acquisitions, Magn. Reson. Med, vol.72, pp.93-102, 2014. ,
Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced gfactor penalty, Magn. Reson. Med, vol.67, pp.1210-1224, 2012. ,
DOI : 10.1002/mrm.23097
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.23097
Optimized Phase Schedules for Minimizing Peak RF Power in Simultaneous Multi ,
, Slice RF Excitation Pulses, Proceedings of the 20th Annual Meeting of ISMRM, p.2209, 2012.
Nuclear magnetic resonance signal from flowing nuclei in rapid imaging using gradient echoes, Med. Phys, vol.15, pp.809-814, 1988. ,
Gadgetron: an open source framework for medical image reconstruction, Magn. Reson. Med, vol.69, pp.1768-1776, 2013. ,
DOI : 10.1002/mrm.24389
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.24389
Generalized autocalibrating partially parallel acquisitions (GRAPPA), Magn. Reson. Med, vol.47, pp.1202-1210, 2002. ,
DOI : 10.1002/mrm.10171
Sparse MRI: The application of compressed sensing for rapid MR imaging, Magn. Reson. Med, vol.58, pp.1182-1195, 2007. ,
SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space, Magn. Reson. Med, vol.64, pp.457-471, 2010. ,
DOI : 10.1002/mrm.22428
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.22428
Partial Fourier imaging in multi-dimensions: A means to save a full factor of two in time, J. Magn. Reson. Imaging, vol.14, pp.628-635, 2001. ,
MR image reconstruction of sparsely sampled 3D kspace data by projection-onto-convex sets, Magn. Reson. Imaging, vol.24, pp.761-773, 2006. ,
DOI : 10.1016/j.mri.2005.12.028
Evaluation of slice accelerations using multiband echo planar imaging at 3 T, NeuroImage, vol.83, pp.991-1001, 2013. ,
DOI : 10.1016/j.neuroimage.2013.07.055
URL : http://europepmc.org/articles/pmc3815955?pdf=render
Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart: A Statement for Healthcare Professionals From the Cardiac Imaging Committee of the Council on, Clinical Cardiology of the American Heart Association. Circulation, vol.105, pp.539-542, 2002. ,
Inversion recovery at 7 T in the human myocardium: measurement of T(1), inversion efficiency and B(1) (+), Magn. Reson. Med, vol.70, pp.1038-1046, 2013. ,
Motion-Corrected, Super-Resolution Reconstruction for High-Resolution 3D Cardiac Cine MRI, Medical Image Computing and Computer-Assisted Intervention -MICCAI 2015, pp.435-442, 2015. ,
DOI : 10.1007/978-3-319-24574-4_52
URL : https://hal.archives-ouvertes.fr/hal-01737189
Two-dimensional-NGC-SENSE-GRAPPA for fast, ghosting-robust reconstruction of in-plane and slice-accelerated blipped-CAIPI echo planar imaging, Magn. Reson. Med, vol.77, pp.998-1009, 2017. ,
,
, Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI, IEEE Trans. Med. Imaging, vol.35, pp.1824-1836, 2016.
DREAM-a novel approach for robust, ultrafast, multislice B1 mapping, Magn. Reson. Med, vol.68, pp.1517-1526, 2012. ,
DOI : 10.1002/mrm.24158
URL : https://onlinelibrary.wiley.com/doi/pdf/10.1002/mrm.24158
A specific absorption rate reduction method for simultaneous multislice magnetic resonance imaging, Rev. Sci. Instrum, vol.88, p.43701, 2017. ,
DOI : 10.1063/1.4979861
Optimized amplitude modulated multiband RF pulse design, Magn. Reson. Med, vol.78, pp.2185-2193, 2017. ,
Variable-rate selective excitation, J. Magn ,
DOI : 10.1016/0022-2364(88)90131-x
, , vol.78, pp.440-458, 19691988.