Impact of Switching from Intermittently Scanned to Real-Time Continuous Glucose Monitoring Systems in a Type 1 Diabetes Patient French Cohort: An Observational Study of Clinical Practices - Aix-Marseille Université Accéder directement au contenu
Article Dans Une Revue Diabetes Technology and Therapeutics Année : 2020

Impact of Switching from Intermittently Scanned to Real-Time Continuous Glucose Monitoring Systems in a Type 1 Diabetes Patient French Cohort: An Observational Study of Clinical Practices

Résumé

Aim: Assess the impact of switching from intermittently scanned (FreeStyle Libre [FSL]) to real-time (Dexcom G4 platinum [DG4]) continuous glucose monitoring systems on glycemia control in type 1 diabetes (T1D) patients with high risk of hypoglycemia and/or elevated glycated hemoglobin (HbA1c). Methods: We conducted an observational study in 18 T1D adults with poor glycemic control on FSL. Ambulatory glucose profile data were collected during the last 3 months of FSL use before inclusion (M0 period), during the first 3 months (M3 period) and the last 3 months (M6 period) of DG4 use. Data were then expressed as 24-h averages. Biological HbA1c was measured for all three periods. Patients were their own-controls and statistics were performed using paired t-test or Wilcoxon for matched-pairs. Results: The switch to DG4 at M3 resulted in a higher time-in-range (TIR) 70-180 mg/dL (median [Q1;Q3], 53.1 [44.5;67.3] vs. 41.5 [28.5;62.0], P = 0.0008), and a lower time-below-range <70 mg/dL (TBR mean-standard deviation (SD), 5.4-3.7 vs. 10.9-7.1, P = 0.0009) and in the glucose % coefficient of variation (%CV mean-SD, 40.1 vs. 46.9, P = 0.0001). Mean (SD) changes were +10.3 (8.0) percentage points for TIR,-5.5 (5.8) percentage points for TBR, and-6.8 (5.8) percentage points for %CV. These results were confirmed at the M6 period. Conclusions: Switching from FSL to DG4 appears to provide a beneficial therapeutic option without changing insulin delivery systems, regardless of the origin of the patient's initial glycemic issue.
Fichier principal
Vignette du fichier
Préau Y et al. DTT2021.pdf (655.24 Ko) Télécharger le fichier
Origine : Publication financée par une institution

Dates et versions

hal-03075368 , version 1 (16-12-2020)

Licence

Paternité

Identifiants

Citer

Yannis Préau, Martine Armand, Sébastien Galie, Pauline Schaepelynck, Denis Raccah. Impact of Switching from Intermittently Scanned to Real-Time Continuous Glucose Monitoring Systems in a Type 1 Diabetes Patient French Cohort: An Observational Study of Clinical Practices. Diabetes Technology and Therapeutics, 2020, ⟨10.1089/dia.2020.0515⟩. ⟨hal-03075368⟩
77 Consultations
124 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More