Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system - Aix-Marseille Université Accéder directement au contenu
Article Dans Une Revue Heart Rhythm Année : 2020

Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system

Lucas V.A. Boersma

Résumé

BACKGROUND Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT system; EBR Systems, Sunnyvale, CA), without the requirement for lifelong anticoagulation. OBJECTIVE The purpose of this study was to assess the safety and efficacy of the WiSE-CRT system during real-world clinical use in an international registry. METHODS Data were prospectively collected from 14 centers implanting the WiSE-CRT system as part of the WiCS-LV Post Market Surveillance Registry. (ClinicalTrials.gov Identifier: NCT02610673). RESULTS Ninety patients from 14 European centers underwent implantation with the WiSE-CRT system. Patients were predominantly male, age 68.2 +/- 10.5 years, left ventricular ejection fraction 30.6% +/- 8.9%, mean QRS duration 180.7 +/- 27.0 ms, and 40% with ischemic etiology. Successful implantation and delivery of BiV ENDO pacing was achieved in 94.4% of patients. Acute (<24 hours), 1- to 30-day, and 1- to 6-month complications rates were 4.4%, 18.8%, and 6.7%, respectively. Five deaths (5.6%) occurred within 6 months (3 procedure related). Seventy percent of patients had improvement in heart failure symptoms. CONCLUSION BiV ENDO pacing with the WiSE-CRT system seems to be technically feasible, with a high success rate. Three procedural deaths occurred during the study. Procedural complications mandate adequate operator training and implantation at centers with immediately available cardiothoracic and vascular surgical support.
Fichier principal
Vignette du fichier
PIIS1547527120301922.pdf (832.3 Ko) Télécharger le fichier
Origine : Publication financée par une institution

Dates et versions

hal-03148806 , version 1 (22-02-2021)

Licence

Paternité - Pas d'utilisation commerciale - Pas de modification

Identifiants

Citer

Benjamin J. Sieniewicz, Timothy R Betts, Simon James, Andrew Turley, Christian Butter, et al.. Real-world experience of leadless left ventricular endocardial cardiac resynchronization therapy: A multicenter international registry of the WiSE-CRT pacing system. Heart Rhythm, 2020, 17 (8), pp.1291-1297. ⟨10.1016/j.hrthm.2020.03.002⟩. ⟨hal-03148806⟩
74 Consultations
29 Téléchargements

Altmetric