Absolute Temperature Measurement on tungsten surfaces with monochrome and bicolor IR thermography

Résumé

ITER (https://www.iter.org) will take advantage of tungsten (W) actively cooled Plasma Facing Units (PFU) in the lower divertor. These PFUs will receive a steady state plasma heat flux of 10 MW/m² and up to 20 MW/m² in slow transients, pushing these components to their limit. For machine protection reasons and for the study of the plasma wall interactions, temperature measurements are foreseen with Mid Wave Infra-Red (MWIR: 3-5 µm) thermography systems to cover most of ITER chamber including the divertor (tungsten material) and first wall (beryllium material) [1]. Absolute temperature measurements from 70 °C, the cooling temperature of the PFUs, up to 3500 °C (W melting temperature at 3422 °C), are considered. Those measurements require the knowledge of the emissivity of the tungsten PFU surfaces as function of the temperature and wavelength used for the IR monochrome thermography system. This paper summarizes the emissivity measurements performed on tungsten surfaces in High Heat Flux (HHF) test beds and the WEST tokamak [2] and uses the experimental emissivity values to compute the expected uncertainties in ITER (T/T) using monochrome and bicolor thermography techniques. Results show that monochrome technique is not able to fulfill the T/T < 10% requirement, while bicolor technique is able to reduce the temperature uncertainty below 10%. Laboratory bicolor thermography measurements using a filter wheel (including 6 MWIR interference filters) have been successfully performed up to 830°C with temperature uncertainty T/T < 3%. In the WEST tokamak, the two dimensions emissivity map is varying by a factor of five within 27 cm along a PFU, from 0.13 to 0.65, showing that the monochrome IR thermography will have difficulties to stay within the ITER requirements T/T < 10% from 70 °C up to 3500 °C.
Fichier principal
Vignette du fichier
Guilhem_2021_NF_preprint.pdf (2.08 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03579912 , version 1 (18-02-2022)

Licence

Paternité - Pas d'utilisation commerciale - Pas de modification

Identifiants

Citer

D Guilhem, Y Corre, X Courtois, J Gaspar, C Pocheau, et al.. Absolute Temperature Measurement on tungsten surfaces with monochrome and bicolor IR thermography. Nuclear Fusion, In press, ⟨10.1088/1741-4326/ac0e73⟩. ⟨hal-03579912⟩
31 Consultations
69 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More