Comparative Assessment of the Sensitivity of Ten Commercial Rapid Diagnostic Test Kits for the Detection of Plasmodium - Aix-Marseille Université Accéder directement au contenu
Article Dans Une Revue Diagnostics Année : 2022

Comparative Assessment of the Sensitivity of Ten Commercial Rapid Diagnostic Test Kits for the Detection of Plasmodium

Résumé

Malaria is one of the most common tropical diseases encountered by members of the French military who are deployed in operations under constrained conditions in malaria-endemic areas. Blood smear microscopy—the gold standard for malaria diagnosis—is often not available in such settings, where the detection of malaria relies on rapid diagnostic tests (RDTs). Ten RDTs (from Biosynex, Carestart, Humasis, SD Bioline, and CTK Biotech), based on the detection of the Plasmodium falciparum histidine-rich protein 2 (HRP2) or lactate dehydrogenase (pLDH, PfLDH, or PvLDH), were assessed against 159 samples collected from imported malaria cases, including 79 P. falciparum, 37 P. vivax, 22 P. ovale, and 21 P. malariae parasites. Samples had been previously characterised using microscopy and real-time PCR. The overall sensitivities for the Plasmodium test ranged from 69.8% (111/159) to 95% (151/159). There was no significant difference for the specific detection of P. falciparum (96.2% to 98.7%, p = 0.845). No significant difference was found between sensitivities to P. vivax by pan LDH or pvLDH (81.1% (30/37) to 94.6% (35/37) (p = 0.845)). Some of the RDTs missed most of P. ovale and P. malariae, with sensitivities for all RDTs ranging respectively from 4.5% (1/22) to 81.8% (18/22) and 14.3% (3/21) to 95.2% (20/21). Carestart Malaria Pf/Pan (pLDH) Ag G0121, a pLDH-based RDT (PfLDH and pLDH), showed the highest sensitivities to P. falciparum (98.7%, 78/79), P. vivax (94.6%, 35/37), P. ovale (81.8%, 18/22), and P. malariae (95.2%, 20/21) and meets the requirements for military deployments in malaria-endemic areas.
Fichier principal
Vignette du fichier
diagnostics-12-02240-v2.pdf (277.59 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Licence : CC BY - Paternité

Dates et versions

hal-03948586 , version 1 (25-08-2023)

Licence

Paternité

Identifiants

Citer

Mathieu Gendrot, Marylin Madamet, Isabelle Fonta, Nicolas Benoit, Rémy Amalvict, et al.. Comparative Assessment of the Sensitivity of Ten Commercial Rapid Diagnostic Test Kits for the Detection of Plasmodium. Diagnostics, 2022, 12 (9), pp.2240. ⟨10.3390/diagnostics12092240⟩. ⟨hal-03948586⟩
29 Consultations
10 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More